b2科目四模拟试题多少题驾考考爆了怎么补救
b2科目四模拟试题多少题 驾考考爆了怎么补救

获取显示信息: 制造商,品牌等.

电脑杂谈  发布时间:2020-08-15 01:02:49  来源:网络整理

获取显示器厂商_中海达手簿显示获取主板信息_多轴器厂商

wmi可以获得一些基本信息,但是制造商品牌等似乎无法获取它:

On Error Resume Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_DesktopMonitor",,48)
For Each objItem in colItems
    Wscript.Echo "Availability: " & objItem.Availability
    Wscript.Echo "Bandwidth: " & objItem.Bandwidth
    Wscript.Echo "Caption: " & objItem.Caption
    Wscript.Echo "ConfigManagerErrorCode: " & objItem.ConfigManagerErrorCode
    Wscript.Echo "ConfigManagerUserConfig: " & objItem.ConfigManagerUserConfig
    Wscript.Echo "CreationClassName: " & objItem.CreationClassName
    Wscript.Echo "Description: " & objItem.Description
    Wscript.Echo "DeviceID: " & objItem.DeviceID
    Wscript.Echo "DisplayType: " & objItem.DisplayType
    Wscript.Echo "ErrorCleared: " & objItem.ErrorCleared
    Wscript.Echo "ErrorDescription: " & objItem.ErrorDescription
    Wscript.Echo "InstallDate: " & objItem.InstallDate
    Wscript.Echo "IsLocked: " & objItem.IsLocked
    Wscript.Echo "LastErrorCode: " & objItem.LastErrorCode
    Wscript.Echo "MonitorManufacturer: " & objItem.MonitorManufacturer
    Wscript.Echo "MonitorType: " & objItem.MonitorType
    Wscript.Echo "Name: " & objItem.Name
    Wscript.Echo "PixelsPerXLogicalInch: " & objItem.PixelsPerXLogicalInch
    Wscript.Echo "PixelsPerYLogicalInch: " & objItem.PixelsPerYLogicalInch
    Wscript.Echo "PNPDeviceID: " & objItem.PNPDeviceID
    Wscript.Echo "PowerManagementCapabilities: " & objItem.PowerManagementCapabilities
    Wscript.Echo "PowerManagementSupported: " & objItem.PowerManagementSupported
    Wscript.Echo "ScreenHeight: " & objItem.ScreenHeight
    Wscript.Echo "ScreenWidth: " & objItem.ScreenWidth
    Wscript.Echo "Status: " & objItem.Status
    Wscript.Echo "StatusInfo: " & objItem.StatusInfo
    Wscript.Echo "SystemCreationClassName: " & objItem.SystemCreationClassName
    Wscript.Echo "SystemName: " & objItem.SystemName
Next

其中一个字段PNPDeviceID显示可能的品牌:

---------------------------
Windows Script Host
---------------------------
PNPDeviceID: DISPLAY\DELD036\5&60ECEDB&0&UID1048833
---------------------------

可以看出,wmi的信息还不够. 您可以通过EDID获得信息,例如制造商和品牌. 此信息在注册表中:

多轴器厂商_获取显示器厂商_中海达手簿显示获取主板信息

HKEY_LOCAL_MACHINE \ SYSTEM \ ControlSet001 \ Enum \ DISPLAY \ DELD036 \ 5&60ecedb&0&UID1048833 \ Device Parameters

在EDID中.

EDID: 扩展显示标识数据(扩展显示标识数据)是一种VESA标准数据格式,其中包含与显示器及其性能相关的参数,包括供应商信息,最大图像尺寸,颜色设置,制造商预设,频率范围和显示名称和序列号的字符串. 此信息存储在显示部分中,并用于通过DDC(显示数据通道)与系统通信,该DDC在显示器和PC图形适配器之间执行. EDID的最新版本可用于CRT,LCD和将来的显示类型,因为EDID提供了几乎所有显示参数的一般说明.

EDID由128个字节组成,大致划分如下

0-7: 标头信息,8字节,由00 FF FF FF FF FF FF FF 00组成

多轴器厂商_获取显示器厂商_中海达手簿显示获取主板信息

8-9: 供应商ID

10-11: 产品ID

12-15: 32位序列号

16-17: 制造日期

18-19: EDID版本

获取显示器厂商_多轴器厂商_中海达手簿显示获取主板信息

20-24: 显示屏的基本信息(电源,最大高度,宽度)

25-34: 显示器的颜色特征

35-37: 显示的基本时间,时间,分辨率

38-53: 标准时间和显示时间

54-125: 详细的显示时间和显示时间

多轴器厂商_获取显示器厂商_中海达手簿显示获取主板信息

126: 扩展标志位,EDID-1.3版本需要忽略,设置为0

127: 总和验证值

获取信息,例如:

转载于:


本文来自电脑杂谈,转载请注明本文网址:
http://www.pc-fly.com/a/tongxinshuyu/article-299056-1.html

    相关阅读
      发表评论  请自觉遵守互联网相关的政策法规,严禁发布、暴力、反动的言论

      • 天条院沙姫
        天条院沙姫

        卖武器就是他要达到的目的

      • 李卓燃
        李卓燃

        兼顾监视外国军舰动向

      热点图片
      拼命载入中...